Facts checked 2026-11-15.

Texas leaves kitchen hoods to the cities. There is no statewide mechanical permit, so the rules depend on where the kitchen sits. Texas Commercial Kitchen Connect passes your hood, fan or make-up air request to a mechanical contractor that serves your ZIP code. The contractor does the work and pulls the permits.
Two cities, two codes
Houston and Dallas show how far apart neighbors can be.
| City | Mechanical code in force |
|---|---|
| Houston | 2021 Uniform Mechanical Code with Houston amendments |
| Dallas | 2021 International Mechanical Code with Dallas amendments |
A hood drawing that passed in one city can fail in the other. Ask the local permit office which edition applies before the design is final.
Houston's mechanical section
In Houston, a new or replacement kitchen ventilation system needs a mechanical permit and an inspection. The Mechanical Inspections section answers hood questions and registers licensed HVAC contractors. Cover, grill seal and final inspections are normally called in by the contractor. The city also lists a PCC test for commercial kitchen ventilation.
Get prices for this job. Send one request and pick how many local companies quote it.
Get quotesDallas and the sprinkler line
Dallas adopted the 2021 mechanical and plumbing codes with its own changes. Its fire code text calls for a sprinkler in the hood and duct system where sprinklers are how the kitchen meets the fire-extinguishing section. Its fee schedule has a separate permit line for kitchen fire-extinguishing systems.
One checklist from a smaller city
Midlothian's fire marshal publishes what an inspector looks at on a kitchen. Its list asks for a Type I hood with UL 300 suppression and a smoke test of the duct joints and welds. It also wants fire wrap on the ducts, gas and power cut when the suppression trips, and a state tag once the work is accepted. The fan keeps running after a trip. Other cities publish their own lists, so ask yours.
Does the installer need a state license?
The state air conditioning and refrigeration license does not reach the hood itself. The Occupations Code exempts a person who installs, repairs or removes a vent hood of the type used in kitchens. Ducts, fans and make-up air are another matter, and a city may call them mechanical work. Ask the permit office who may pull the permit. Where a state license is required for the work, we check it before passing a request on.
What the health inspector looks for
A health inspector views the hood from the food side. Filters should come out easily for cleaning, and grease or condensation should not drip on food, equipment or utensils.
Who does what
- Mechanical office: permits and inspects the hood and exhaust.
- Fire marshal: the suppression system and grease cleaning.
- Health department: filters and drip control.
Before the contractor calls
Know whether the job is a new hood, a new fan or a replacement. Have the cooking equipment list, the address and the building type ready. Cleaning has its own page, and so does the suppression system.
Questions
Does a new restaurant hood need a permit in Texas?
In Houston a mechanical permit and inspection are needed for commercial kitchen ventilation. Elsewhere, the city permit office has the answer.
Is there a state license for installing a kitchen hood in Texas?
Not under the air conditioning chapter, which exempts kitchen vent hoods. Your city may still set its own permit rules for ducts and fans.
Which mechanical code covers a restaurant hood in Texas?
The city picks it. Houston and Dallas use different mechanical codes, each with local amendments.
Sources
- Houston Mechanical Inspections
- Houston code development, 2021 Houston Construction Code
- Dallas current city codes
- Dallas 2021 International Fire Code amendments, ordinance 23-0118
- Dallas Fire-Rescue schedule of permit fees
- Midlothian Fire Marshal's Office, fire protection inspections
- Occupations Code 1302.060, vent hoods
- FDA Food Code 2017, sections 4-202.18 and 4-204.11